Large Selection of Dimplex Koolant Koolers Water Chillers!

Dimplex Koolant Koolers
Water Chillers

Dimplex Chillers

Koolant Koolers is a division of Dimplex Thermal Solutions and manufactures standard and custom cooling solutions for industrial applications - machine tool, food processing, medical and more. These reliable and affordable chilling solutions are offered by T. J. Snow.

J Series Models

  • Air-cooled, closed loop
  • Brushed stainless steel cabinet
  • Digital temperature controller
  • Hermetic compressor
  • Manual fluid bypass
  • Bypass regulator valve
  • Discharge pressure gauge
  • Flush-mounted fill port
  • Wire connection panel
  • Heavy duty casters
  • 12 month warranty

S Series Models

  • UL 1995 certification
  • 12 months warranty
  • Air-cooled, closed loop
  • Digital temperature controller
  • Hermetic compressor
  • Brazed plate evaporator
  • Hot gas regulator
  • Fused disconnect
  • Vertical air discharge
  • Cleanable air filters
  • Manual bypass
  • Fluid level sight glass
  • Seamless plastic tank
  • R407C Refrigerant
 

Product Selections

*Capacity is based on 65°F fluid setpoint and 95°F ambient.

Koolant KoolersCapacityElectricalTank VolumePortDimensions
J SeriesBtu’s/HrTonsVolts/Phase/ HertzGallonsGPMPSINPT (inches)LengthWidthHeight
JHI-180-M2,1001/8115/1/6052501/221.752128.5
JHI-500-M5,0001/2115/1/6054501/221.752128.5
JHI-500-M5,5001/2230/1/6054501/221.752128.5
JHI-1000-M11,3001230/1 /60104501 or 1/230.62525.12535.25
JHI-1000-M11,3001230/3/6010450 or 351 or 1/230.62525.12535.25
JHI-1000-M11,3001460/3/6010450 or 351 or 1/230.62525.12535.25
JHI-1500-M18,4081.5230/1/60104501/230.62525.12535.25
JHI-1500-M18,0001.5460/3/6010450 or 351 or 1/230.62525.12535.25
JHI-2000-M24,0002230/1/60101035137.7532.7533.25
JHI-2000-M24,0002230/3/60101035137.7532.7533.25
JHI-2000-M24,0002460/3/60101035137.7532.7533.25
S SeriesBtu’s/HrTonsVolts/Phase/ HertzGallonsGPMPSINPT (inches)LengthWidthHeight
* Indoor
SVI-3000-M36,0003230/3/603630381.5353768
SVI-3000-M36,0003460/3/603630381.5353768
SVI-5000-M60,0005230/3/603640451.5353768
SVI-5000-M60,0005460/3/603640451.5353768
SVI-7500-M90,0007.5460/3/606040452573768
SVI-10000-M120,00010460/3/606070382573768
SVI-15000-M180,00015460/3/6086120422576068
SVI-20000-M240,00020460/3/6086120422576068
** Outdoor
SVO-3000-M36,0003230/3/603630381.5353768
SVO-3000-M36,0003460/3/603630381.5353768
SVO-5000-M60,0005230/3/603640451.5353768
SVO-5000-M60,0005460/3/603640451.5353768
SVO-7500-M90,0007.5460/3/606040452573768
SVO-10000-M120,00010460/3/606070382573768
SVO-15000-M180,00015460/3/6086120422576068
SVO-20000-M240,00020460/3/6086120422576068
*** Weld Package Indoor
SVI-3000-W-M36,0003230/3/603630381.5353768
SVI-3000-W-M36,0003460/3/603630381.5353768
SVI-5000-W-M60,0005230/3/603640451.5353768
SVI-5000-W-M60,0005460/3/603640451.5353768
SVI-7500-W-M90,0007.5460/3/606040452573768
SVI-10000-W-M120,00010460/3/606070382573768
SVI-15000-W-M180,00015460/3/6086120422576068
SVI-20000-W-M240,00020460/3/6086120422576068

Notes:

All S Series units include Hot Gas Regulator and Manual Bypass valve.

* Standard Indoor Units “S” these units are designed to run on straight water or water/glycol.

** Outdoor Units “O” will come standard with galvanized sheet metal, a Ranco controller and Variable Frequency Drive (VFD) for fan control. Units can be used outdoors in temperatures ranging from -20F to 95F.

*** Weld Package Indoor “-W” will come standard with Auto Water Fill, Inlet Water Filter, Hot Gas Regulator, and Pump Flow Upgrade. These units are designed for straight water use or water/glycol.

Hot gas regulator– are included on all units for straight water or water/glycol.

Auto Water Fill – Automatically maintains the water level of the reservoir. Customer needs to supply water line to the automatic controller.

Inlet Water Filter – Blue housing. This kit includes an inlet water filter housing and (2) 50 micron filter cartridges for filtering the return line from the process.

Pressure Relief Bypass – Allows for situations where the system maximum operating pressure may be exceeded by the pumps deadhead pressure.

Anti Backflow Kit – This feature prevents any back flow through the chiller when the chiller is turned off. This option is used in situations where the chiller is installed below the processing equipment. It can also be used in an installation where overhead piping causes a back flow through the chiller when the unit is turned off.

Casters – High quality caster are used and shipped loose with the unit.

Pump Upgrade Pressure – in higher pressure applications this option is selected to allow pressure up to 80psi. 3 gallons per ton will be used to calculate the flow on these pump upgrades.

Pump Upgrade Flow – This option allows you to increase the amount of flow when the standard flows will not produce enough for your application. Please note the PSI as well as it has changed with the flow changes.

Remote Controls – in outdoor applications this option is selected to allow the customer to have control over the set point and on/off capabilities from indoors. Maximum length of remote run is 400ft. Customer is responsible for the wiring connections between the chiller and the remote controls.