TJ Snow is an authorized distributor of Unitrol’s quality water chillers, manufactured in the USA since 1971. Water chillers play a crucial role in the operation of spot welders by efficiently regulating the temperature of the welding electrodes. Because of the intense heat generated during the resistance welding process, water chillers are integrated into the welding system to maintain optimal electrode temperatures by circulating chiller water through a closed-loop system.
MODEL 8000 CHILLER
4,000 BTU/Hr (1/3 TON)
The 8000 is a self contained system that is manually refilled. This chiller is ideal for portable applications such as robotics, or where plant layout precludes the use of a central chiller. Because of its small size, the Model 8000 is an ideal choice for OEM packaging into industrial machinery or laboratory equipment.
For welding applications, this model is ideal for cooling one or more TIG or MIG welders with a total capacity of up to 500 amps. It can also be used to cool a single spot welder (30 KVA or smaller).
Standard Features:
Stainless Steel Brazed Plate Condenser
Digital Water Temperature Controller
High & Low Refrigerant Safety System
Brass Positive Displacement Water Pump
Stainless Steel Water Storage Tank
Air Cooled Condenser
Low Water Level Safety System
Audible Fault Alarm
Washable Air Intake Filter
6′ Line Cord & Plug
Available Optional Features:
Casters
Control For Remote Analog Temperature Setting
MODEL 8012 CHILLER
6,000 BTU/Hr (1/2 TON)
The 8012 is a self contained system that is manually refilled. This chiller is ideal for portable applications such as robotics, or where plant layout precludes the use of a central chiller. Because of its small size, the Model 8012 is an ideal choice for OEM packaging into industrial machinery or laboratory equipment.
For welding applications, this model is ideal for cooling one or more TIG or MIG welders with a total capacity of up to 750 amps. It can also be used to cool a single spot welder (50 KVA or smaller).
Standard Features:
Stainless Steel Brazed Plate Condenser
Digital Water Temperature Controller
High & Low Refrigerant Safety System
Brass Positive Displacement Water Pump
Stainless Steel Water Storage Tank
Air Cooled Condenser
Low Water Level Safety System
Audible Fault Alarm
Washable Air Intake Filter
6′ Line Cord & Plug
Available Optional Features:
Casters
Control For Remote Analog Temperature Setting
THE A SERIES
Includes models 8025 through 8111 (¾ to 3¼ tons).
For resistance welding applications, models in this series will chill up to seven spot welders (up to 75 KVA each).
Standard Features:
Stainless Steel Brazed Plate Condenser
Digital Water Temperature Controller
High & Low Refrigerant Safety System
Stainless Steel Centrifugal Water Pump
Automatic Water Refill System
Polyethylene Water Storage Tank
Air Cooled Condenser
Low Water Flow Safety Switch
Water Filter Strainer
Washable Air Intake Filter
Water Pressure Gauge
Available Optional Features:
Water Cooled Condenser
Manual Refill System With Sight Glass
Casters
Split System With Remote Condenser
Low Temperature Kit For Outside Installation
Controller For Remote Analog Temperature Setting
THE B SERIES
Includes models 8200 through 8301 (5 to 10 tons).
For resistance welding applications, models in this series will chill up to 20 spot welders (up to 75 KVA each).
Standard Features:
Stainless Steel Brazed Plate Condenser
Digital Water Temperature Controller
High & Low Refrigerant Safety System
Stainless Steel Centrifugal Water Pump
Automatic Water Refill System
Polyethylene Water Storage Tank
Air Cooled Condenser
Low Water Flow Safety Switch
Water Filter Strainer
Washable Air Intake Filter
Water Pressure Gauge
Check Valve on Water Out Line
Solenoid Valve on Water Return Line
Available Optional Features:
Water Cooled Condenser
Manual Refill System With Sight Glass
Casters
Split System With Remote Condenser
Low Temperature Kit For Outside Installation
Controller For Remote Analog Temperature Setting
THE C SERIES
Includes models 8400 through 8650R (15 to 50 tons). This series is typically used for central plant and large process water applications.
For resistance welding applications, models in this series will chill up to 100 spot welders (up to 75 KVA each).
Standard Features:
Three Pole Circuit Breaker/Disconnect
Remote Condenser on Models With “R” In Model Number
Stainless Steel Brazed Plate Condenser
2-Stage Digital Water Temperature Controller
Water Freeze Safety System
High & Low Refrigerant Safety System
Centrifugal Water Pump
Automatic Water Refill System
Polyethylene Water Storage Tank
Air Cooled Condenser
Low Water Flow Safety Switch
Water Filter Strainer
Washable Air Intake Filter
Water Pressure Gauge
Check Valve on Water Out Line
Solenoid Valve on Water Return Line
Dual Staged Compressors For Models 8400-8451
Double Stage Compressor With Unloader on Models 8500-8650R
Low Pressure Pump Down Between Cycles on Models 8500-8650R
Available Optional Features:
Water Cooled Condenser
Manual Refill System With Sight Glass
Split System With Remote Condenser (Standard On 8550R-8650R Models)
Using Unitrol Chillers for Resistance Welding Applications
UNITROL chillers are designed to handle a large variety of industrial water cooling applications. Over the years, UNITROL has produced a large volume of chillers for use in resistance (spot) welding applications. Our experience in sizing chillers used in welding lines allows us to provide the most economical match of chiller and application.
Why You Need the Unitrol System for Your Welding Line
All UNITROL Spot Welder Chillers are self-contained, closed-loop refrigeration systems which recirculate a continuous supply of cold water virtually eliminating all water consumption. This means it’s unnecessary to use city or well water which presently contaminates your water lines. So down-time for cleaning and descaling of mineral deposits is totally eliminated.
Consistent pressure and low temperature is also maintained in the cooling water, helping to reduce down-time for copper tip replacement as much as 50%. Your weld quality and uniformity is also greatly improved. The result is increased production, more efficient operation, more actual output hours. After all, it’s only when your machines are running that you’re turning out billable product.
Unitrol Chillers Pay for Themselves in the First Year
You will immediately realize an impressive increase in quality production and output hours with drastic reduction of costly tip replacement. As an example, an elimination of as little as 10 minutes per day of tip dressing represents a typical annual savings per operator of over $1,000.00. By adding the elimination of costly water, high sewer taxes, and EPA mandated water processing, you can easily realize a payback of the entire chiller cost within 5 to 12 months.
Another money saving tip: The air exhaust from the chiller can be used to heat your building, and the heat can be exhausted out during the warm months.
Why Buy Unitrol Chillers?
Unitrol has since 1971 only manufactured “automotive grade” chillers which come complete with features that are extra cost or not available on their line of “commercial grade” chillers. And yet the cost to you is about the same. And when you add the cost they charge as options for these features, Unitrol comes out at a lower cost.
These features are supplied at no extra cost to handle continuous operation at full capacity under the harshest of industrial conditions:
Automatic water refill system to keep tank full even with leaks outside chiller (not on model 8000)
Backflow safety kit to prevent water overflow in tank when system is shut off. Kit includes zero pressure water solenoid valve, and check valve (5-ton and larger chillers).
Pressure bypass water system to keep flow through evaporator above minimum requirements. Allows operation at all outside water flow rates (except model 8000 mini-chiller)
Washable air intake filter to keep condenser clean and maintain efficiency
Cleanable filter/strainer on water return prevents contaminants from reducing the efficiency of the cooling evaporator and also prolongs the life of the water pump. This component can be flushed without draining or turning off the chiller.
Stainless Steel “brazed plate” evaporators, mounted outside of water tank. Because of the flow rate through this evaporator the system is self-cleaning Washable filter on air intake eliminates the need to continuously clean condenser coils. This is a major advantage when it comes time for service of the chiller.
Stainless Steel water pumps with ceramic seals
Non-metallic water tank with non-metallic and brass fittings.
5 Ton through 10 Ton Water Chillers
Electronic digital temperature controller. These controllers are staged for maximum efficiency on 15-ton chiller
Low water flow safety system to protect refrigeration components stops the compressor if a fault occurs that could freeze the system
All water passage fittings are non-ferrous to prevent internal rust accumulation
Low pressure and High Freon safety system
Fault indicator lights for Freon and Low Water Flow faults
Ability to service or inspect chiller “hot” with all panels removed
Outdoor Applications:
Chillers can be ordered with outdoor kits installed for use in any ambient temperature.
Typical Applications:
RESISTANCE (SPOT WELDERS)
INDUCTION WELDERS AND FURNACES
MIG AND TIG WELDERS
HYDRAULIC FLUID COOLING
X-RAY AND OTHER MEDICAL EQUIPMENT
LASERS
ABRASIVE CUTTING
CHEMICAL AND PHARMACEUTICAL
FOOD AND BEVERAGE
LABORATORY
MEDICAL CHILLERS
Customizing a UNITROL Chiller:
UNITROL can modify any chiller model to handle special applications such as:
Electrical: 380V or 575V, 50Hz frequency
Water Pumps: Special flow or pressure requirements
Dual Water Pumps: One pump for internal refrigeration, one for outside load
Added Cooling Loops: To chill more than one circuit (Often used for Seam Welding flood cooling)
Split systems to place heat-producing condenser outside of building
Manual water refill with sight glass to replace automatic refill system
Alarms and interlocking systems
Non-Refrigerated Coolers:
UNITROL also manufactures non-refrigerated systems that will cool water down to as low as 5°F above room temperature. These systems include a fine-finned radiator, water tank, water pump and controls. Sizes range from nominal 24,000 BTU/Hr to 1,000,000 BUT/Hr. Contact UNITROL sales to select the appropriate model number.
Water Cooled Chillers:
Standard model chillers are provided with Air Cooled Condensers. UNITROL can also provide any of our chillers with Water Cooled Condensers.
Water Chiller and Inline Booster Master Chart
CHILLERS: These units are self-contained and include a WATER TANK and WATER PUMP. Chillers recirculate water and are considered “Closed Loop” systems.
INLINE BOOSTERS: Boosters use water supplied from an outside source and do not include a WATER TANK or WATER PUMP. Inline Boosters do not recirculate water.
NOTES:
*: CHILLERS include a WATER TANK and WATER PUMP. Other size water pumps are available to produce higher water pressure or water flow rates.
**: INLINE BOOSTERS use water pushed from an outside source and do not include a WATER TANK or WATER PUMP.
***: REMOTE CONDENSER: Models ending with “R” are shipped in two pieces. The inside component contains water tank, water pump, controls, and cooling evaporator. The outdoor component contains compressor, and heat-producing condenser. Customer field installation of refrigeration piping and electrical control lines is required. Dimensions shown are for the inside components only.
#: RESISTANCE WELDING APPLICATIONS: When used to chill resistance welders. This column is calculated to cool up to the listed quantity of 75 KVA or smaller single point spot welders under typical conditions. For other applications consult Unitrol for sizing assistance.
##: These Models are dual compressor systems. They are supplied in two modules, each with the dimensions shown. The total weight for the two modules is as shown on the chart.
MODEL 8000 is designed to chill one spot welder (40 KVA or smaller) or up to two 250A TIG welders. It can also be used for small laboratory processes.
Cookie Consent
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Cookie Preferences
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
Name
Description
Duration
Geolocation Config
This cookie is used to store the consent settings based on the visitor's location.
30 days
Cookie Preferences
This cookie is used to store the user's cookie consent preferences.
30 days
CloudFlare provides web performance and security solutions, enhancing site speed and protecting against threats.
The cf_use_ob cookie informs Cloudflare to fetch the requested resource from the Always Online cache on the designated port. Applicable values are: 0, 80, and 443. The cf_ob_info and cf_use_ob cookies are persistent cookies that expire after 30 seconds.
session
__cfwaitingroom
The __cfwaitingroom cookie is only used to track visitors that access a waiting room enabled host and path combination for a zone. Visitors using a browser that does not accept cookies cannot visit the host and path combination while the waiting room is active.
session
cf_chl_rc_i
These cookies are for internal use which allows Cloudflare to identify production issues on clients.
session
cf_chl_rc_ni
These cookies are for internal use which allows Cloudflare to identify production issues on clients.
session
cf_chl_rc_m
These cookies are for internal use which allows Cloudflare to identify production issues on clients.
session
__cfruid
Used by the content network, Cloudflare, to identify trusted web traffic.
session
__cf_bm
Cloudflare's bot products identify and mitigate automated traffic to protect your site from bad bots. Cloudflare places the __cf_bm cookie on End User devices that access Customer sites that are protected by Bot Management or Bot Fight Mode. The __cf_bm cookie is necessary for the proper functioning of these bot solutions.
session
__cflb
When enabling session affinity with Cloudflare Load Balancer, Cloudflare sets a __cflb cookie with a unique value on the first response to the requesting client. Cloudflare routes future requests to the same origin, optimizing network resource usage. In the event of a failover, Cloudflare sets a new __cflb cookie to direct future requests to the failover pool.
session
_cfuvid
The _cfuvid cookie is only set when a site uses this option in a Rate Limiting Rule, and is only used to allow the Cloudflare WAF to distinguish individual users who share the same IP address.
session
cf_clearance
Whether a CAPTCHA or Javascript challenge has been solved.
session
__cfseq
Sequence rules uses cookies to track the order of requests a user has made and the time between requests and makes them available via Cloudflare Rules. This allows you to write rules that match valid or invalid sequences. The specific cookies used to validate sequences are called sequence cookies.
session
cf_ob_info
The cf_ob_info cookie provides information on: The HTTP Status Code returned by the origin web server. The Ray ID of the original failed request. The data center serving the traffic
session
Statistics cookies collect information anonymously. This information helps us understand how visitors use our website.
Azure is Microsoft’s cloud computing platform, offering scalable solutions for storage, analytics, and application development.
Name
Description
Duration
ASLBSACORS
Microsoft App Service and Front Door Affinity Cookies. These cookies are used to direct your browser to use the appropriate backend server.
Session
ASLBSA
Microsoft App Service and Front Door Affinity Cookies. These cookies are used to direct your browser to use the appropriate backend server.
Session
ASPSESSIO
Browsing session: the asterisks identify an alphanumerical code that varies from session to session in automatic mode.
Session
ApplicationGatewayAffinity
This cookie is used by Azure Apps to keep a user session on the same server.
Session
ApplicationGatewayAffinityCORS
This cookie is used by Azure Apps to keep a user session on the same server.
Session
buid
This cookie is used by Microsoft to securely verify your login information
1 month
VisitorStorageGuid
This cookie is used by Azure Apps to keep a user session on the same server.
Session
esctx
This cookie is used by Microsoft to securely verify your login information
session
fpc
This cookie is used by Microsoft to securely verify your login information
session
stsservicecookie
Cookie for Azure Active Directory B2C-verification
session
ARRAffinity
When using Microsoft Azure as a hosting platform and enabling load balancing, this cookie ensures that requests from one visitor's browsing session are always handled by the same server in the cluster.
1 year
ARRAffinitySameSite
When using Microsoft Azure as a hosting platform and enabling load balancing, this cookie ensures that requests from one visitor's browsing session are always handled by the same server in the cluster.
1 year
__AntiXsrfToken
This cookie is used to prevent Cross-site request forgery (often abbreviated as CSRF) attacks of the website. CSRF attacks exploit the trust that a site has in a user's browser.
session
.ASPXANONYMOUS
Created by ASP.Net. This cookie configures anonymous identification for application authorization. This is required to identify entities that are not authenticated when authorization is required.
session
.ASPXAUTH
Created by ASP.Net. .ASPXAUTH is a cookie to identify if the user is authenticated( As user's identity has been verified)
session
nSGt-
This cookie is used by Microsoft to securely verify your Sharepoint login information
session
RpsContextCookie
This cookie is used by Microsoft to securely verify your Sharepoint login information
session
Google Analytics is a powerful tool that tracks and analyzes website traffic for informed marketing decisions.
Used to monitor number of Google Analytics server requests
10 minutes
__utmb
Used to distinguish new sessions and visits. This cookie is set when the GA.js javascript library is loaded and there is no existing __utmb cookie. The cookie is updated every time data is sent to the Google Analytics server.
30 minutes after last activity
__utmc
Used only with old Urchin versions of Google Analytics and not with GA.js. Was used to distinguish between new sessions and visits at the end of a session.
End of session (browser)
__utmz
Contains information about the traffic source or campaign that directed user to the website. The cookie is set when the GA.js javascript is loaded and updated when data is sent to the Google Anaytics server
6 months after last activity
__utmv
Contains custom information set by the web developer via the _setCustomVar method in Google Analytics. This cookie is updated every time new data is sent to the Google Analytics server.
2 years after last activity
__utmx
Used to determine whether a user is included in an A / B or Multivariate test.
18 months
_ga
ID used to identify users
2 years
_gali
Used by Google Analytics to determine which links on a page are being clicked
30 seconds
_ga_
ID used to identify users
2 years
_gid
ID used to identify users for 24 hours after last activity
24 hours
_gat
Used to monitor number of Google Analytics server requests when using Google Tag Manager
1 minute
_gac_
Contains information related to marketing campaigns of the user. These are shared with Google AdWords / Google Ads when the Google Ads and Google Analytics accounts are linked together.
90 days
__utma
ID used to identify users and sessions
2 years after last activity
Microsoft Azure App Insights is a performance management tool for monitoring applications in real time.
Name
Description
Duration
ai_user
-
ai_session
30 minutes
ai_session
This is a unique anonymous session identifier cookie.
Session
ai_user
This is a unique user identifier cookie enabling counting of the number of users accessing the application over time.
1 year
Marketing cookies are used to follow visitors to websites. The intention is to show ads that are relevant and engaging to the individual user.
Bing, powered by Microsoft, is a search engine providing web, image, video, and map search capabilities.
Name
Description
Duration
_uetvid
1 year
_uetsid
24 hours
ToptOut
Records your decision not to receive interest-based advertising delivered by Microsoft.
1 year
ACH01
Maintains information about which ad and where the user clicked on the ad.
End of session (browser)
AADSSO
Microsoft Microsoft Online Authentication Cookie
End of session (browser)
brcap
Microsoft Microsoft Online Authentication Cookie
1 year
MR
Used to collect information for analytics purposes.
6 months
MUID
Identifies unique web browsers visiting Microsoft sites. These cookies are used for advertising, site analytics, and other operational purposes.
1 year
MUIDB
Identifies unique web browsers visiting Microsoft sites. These cookies are used for advertising, site analytics, and other operational purposes.
1 year
MC1
Identifies unique web browsers visiting Microsoft sites. These cookies are used for advertising, site analytics, and other operational purposes.
1 year
MSFPC
Identifies unique web browsers visiting Microsoft sites. These cookies are used for advertising, site analytics, and other operational purposes.
1 year
_uetsid
This cookie is used by Bing to determine what ads should be shown that may be relevant to the end user perusing the site.
30 minutes
_uetvid
This is a cookie utilised by Microsoft Bing Ads and is a tracking cookie. It allows us to engage with a user that has previously visited our website.
16 days
ANON
Contains the A, a unique identifier derived from your Microsoft account, which is used for advertising, personalization, and operational purposes. It is also used to preserve your choice to opt out of interest-based advertising from Microsoft if you have chosen to associate the opt-out with your Microsoft account.
1 year
ANONCHK
Used to store session ID for a users session to ensure that clicks from adverts on the Bing search engine are verified for reporting purposes and for personalisation
10 minutes
CC
Contains a country code as determined from your IP address.
1 year
PPAuth
Helps to authenticate you when you sign in with your Microsoft account.
5 years
MSPAuth
Helps to authenticate you when you sign in with your Microsoft account.
5 years
MSNRPSAuth
Helps to authenticate you when you sign in with your Microsoft account.
5 years
KievRPSAuth
Helps to authenticate you when you sign in with your Microsoft account.
5 years
OID
This cookie is used by the Bing advertising network for advertising tracking purposes.
3 months
OIDI
This cookie is used by the Bing advertising network for advertising tracking purposes.
3 months
OIDR
This cookie is used by the Bing advertising network for advertising tracking purposes.
3 months
BCP
This cookie is used for advertisement tracking purposes.
1 year
BFBUSR
This cookie is used for advertisement tracking purposes.
1 year
BFB
This cookie is used for advertisement tracking purposes.
1 year
ACL
This cookie is used for advertisement tracking purposes.
3 months
ACLUSR
This cookie is used for advertisement tracking purposes.
1 year
MSPTC
This cookie registers data on the visitor. The information is used to optimize advertisement relevance.
1 year
WLSSC
Helps to authenticate you when you sign in with your Microsoft account.
5 years
SRM_B
Collected user data is specifically adapted to the user or device. The usercan also be followed outside of the loaded website, creating a picture of the visitor's behavior.
1 year
MSPProf
Helps to authenticate you when you sign in with your Microsoft account.
5 years
_RwBf
This cookie helps us to track the effectiveness of advertising campaigns on the Bing advertising network.
1 year
MC0
Detects whether cookies are enabled in the browser.
End of session (browser)
_HPVN
Analysis service that connects data from the Bing advertising network with actions performed on the website.
1 year
MS0
Identifies a specific session.
End of session (browser)
_UR
This cookie is used by the Bing advertising network for advertising tracking purposes.
1 year
NAP
Contains an encrypted version of your country, postal code, age, gender, language and occupation, if known, based on your Microsoft account profile.
1 year
MH
Appears on co-branded sites where Microsoft is partnering with an advertiser. This cookie identifies the advertiser, so the right ad is selected.
End of session (browser)
childinfo
Contains information that Microsoft account uses within its pages in relation to child accounts.
5 years
kcdob
Contains information that Microsoft account uses within its pages in relation to child accounts.
5 years
kcrelid
Contains information that Microsoft account uses within its pages in relation to child accounts.
5 years
kcru
Contains information that Microsoft account uses within its pages in relation to child accounts.
5 years
pcfm
Contains information that Microsoft account uses within its pages in relation to child accounts.
When you visit and browse our website and the zoominfo cookie is used, we automatically collect data about you such as your email address and device and browsing information, and we use and share this data with certain vendors to provide certain functionality on our website, analyze which pages you visited, and associate the collected data with
your identity.