Intertron Model 108
Single Phase Resistance Welding Controller with 300 Weld Schedules
Model 108 Face Plate
Features:
- Spot Weld – Seam Weld – Roll Spot Weld – Butt Weld
- Cascade 6 Guns with Clamp Output, Chained or Successive
- Cascade 24 Guns successively, one per Weld Schedule
- Cascade 6 Welding Transformers, Chained or Successive
- Manual Valve Select Program
- Fully Programmable 300 Weld Schedules
- Single – Dual – Triple Foot Switch Control
- 87 Degree Fire Limit Control First Cycle
- 1/2 Cycle Alternate Polarity Firing
- Water Cooled Contactor with Over Temperature Shut Down
- Pulsating Heat Control
- One Time Squeeze Delay in Repeat
- Upslope Heat Control
- Temper Heat Control
- Intermittent Drive Motor On/Off Control
- Forge Delay Start
- Dual Mode Anti-Tie Down Initiation (momentary or push-and-hold)
Optional Features:
- Constant current Control or A.V.C.
- Built-in Weld Current Checker with 1% to 20% Allowable Deviation Error
- with Deviation Error Display and Constant Current or AVC Mode
- Conversion to Model 108A Stepper Heat Control
- Weld/Forge Pressure Control Regulator
- Cylinder Pressure Hi-Low Limit
- Motor Speed Control
- RS 232 Upload/Download Weld Schedules to PC
- RS 232 PLC Control Interface
- Edit Weld Schedule Key Lock
- 108LD Load Distribution over 3 Phase Line with 16 Valve/12 Transformers Manual Valve and Transformer Selection
- 8 Limit Switches Allow Part in Position, Guns Up Detection and Weld Schedule Selection
- 10 Station Intertron Model 375 Scanner
Specificatons:
- INPUT POWER: 200 VAC to 480 VAC 60 HZ.
- AC OUTPUT TO VALVES: 115 VAC 20 VA. EA.
- Solid State Contactors Available in Ranges from 300 Amps to 3200 Amps
- Ignitron Firing Module to Fire Ignitrons Size A through E
- Solid State Relays to Operate Squeeze Valve in Spot – Seam – Roll spot – Cascade – Butt Weld
- End of Sequence Output
- Optional Solid State Relays to Operate Clamp, Retraction, Tip Dress, Upset Valves
- Optional Solid State Relay to Turn on Motor or Air Brake in Seam or Roll spot Mode
- Operating Temperature: 0-50 Degrees Centigrade
- Cabinet Dimensions: 16 5/8″h x 20″w x 11″d
Timing Functions:
Group A 00-99 Weld Schedules
Group B 00-99 Weld Schedules
Group C 00-99 Weld Schedules
- squeeze delay time : 00-99
- squeeze time : 00-99
- impulses : 00-99
- cool time : 00-99
- heat time : 00-99
- heat % : 00-99
- quench time : 00-99
- temper time : 00-99
- temper % : 00-99
- hold time : 01-99
- off time : 00-99
- upslope steps : 00-99
- upslope % heat per step : 0.0-9.9
Intertron Products:
Single Phase:
Three Phase:
Have you lost or destroyed your original Instruction Manual? Ever seen one?
Download and print a replacement for free from T. J. Snow!
108HL STYLE CABINET WITH 2 POLE MAGNETIC BREAKER
Breaker Size: 100 AMPS, 400 AMPS, 600 AMPS
Cabinet Dimensions: 30″(h) x 20″(w) x 11″(d)
108SL STYLE CABINET CASCADE 3 INDIRECT COOLED CONTACTORS