Multiple Schedule/Multiple Sequence 3 Phase DC Controls
Simple to Program
Push buttons and a short three-step procedure make easy work of programming any possible welding schedule.
New Design Reduces Cost
Simplified design significantly reduces production costs which are passed on to you.
Quality Tested to Performance Extremes
Each unit is tested to insure maximum performance at customary operating levels. The Entron resistance welding control has consistently offered an excellent performance history.
Application Flexibility
Transformers can be connected in an Inside Delta, Outside Delta, or “Y” configuration
Features
3 SCR Contactors
Spot Sequence
Pulsation Sequence
Up & Down Slope
Quench/Temper
Forge Delay
Multiple Weld/Multiple Current Sequence
Preheat/Postheat
External Schedule Select
Seam Sequence
Brazing
Flash Welding
Retraction
Squeeze Delay
Stepper
Capabilities
50 Unique Schedules
Chained & Successive Modes
Repeat & Non-Repeat
Weld & Valve Control Relays
3 Valve Outputs
Multiple Weld Programming
Multiple Job Set-Ups
Easily Programmed
Program Only the Functions Required
Advantages
Design Simplicity
Design simplicity is the key to our ability to manufacture the highest quality weld control, the best delivery, and the lowest service requirements in the industry
Field Expandable
ENTRON can provide retrofit controls suitable for any manufacturer’s controls, of any age, type or sequence, for field installation.
Vault Door Locking Mechanism
All cabinet doors equipped with a vault locking mechanism to insure security.
Flexible Applications
EN1003 controls can be applied to spot welders, seam welders, special machines, or robotic equipment for welding a full range of weldable materials.
Multiple Cabinet Options
Available in D, T, L and H cabinet styles with front or side-mounted control panels.
Specifications
Absolute Count:
Push Button Data Entry with Display
Squeeze Count: 0 to 99 cyc, 50/60 Hz
Weld Count/Heat Count: 0 to 99 cyc, 50/60 Hz
Cool Count: 0 to 99 cyc, 50/60 Hz
Hold Count: 0 to 99 cyc, 50/60 Hz
Off Count: 0 to 99 cyc, 50/60 Hz
Weld Impulse Counter: 1 to 99 Impluses
Slope Control/Up and Down Slope: 0 to 99 cyc, 50/60 Hz
Digital Phase Shift Current Control, 10 to 99% in 1% current steps, all weld current functions
It is NOT necessary to program functions NOT required, program only functions required
Standard RWMA/NEMA Programmable Functions
Including the following as examples:
Up Slope and Down Slope
Quench/Temper
Pulsation Sequence
Multi-Weld Count/Multi-Current Select
Pre-Heat/Post-Heat
Forge Delay
Seam Weld (Continuous and Intermittent)
4 Cycle Modes
Non-Repeat: Single Schedule upon initiation
Repeat: Single Schedule repeated with pilot circuit held closed
Successive: Upon each initiation, unique successive schedules are automatically selected
Chained: Multiple schedules can be linked to operate sequentially upon a single initation
Additional Features
Error Code/Fault Outputs
87⁰ First Half Cycle Delayed Firing, Anti-Saturation Circuit
Selectable 50/60 Hz. operation
Dynamic Automatic Voltage Compensation, +20% of Nominal Line
Emergency Stop Circuit
Interlocking Pressure Switch Circuit
Single Stage Pilot/2 Stage Pilot, Beat/Non-Beat Operation
Operational Lights:
3) Power On
3) Weld Current
Indicator Lights for all functions on display panel
Indicator LEDs for pilot inputs and diagnostics
Valve Transformer:150VA 230/460-115V, All Cabinets
3 Valve outputs standard, all controls
Weld Stepper
The EN1003 Series Control is ideal for machines that require either large secondary currents or, by design, have high power losses caused by ferrous metals in the throat of the welder, such as parts of the machine and/or welded parts.
Store up to 50 UNIQUE SCHEDULES
Every parameter of each schedule individually accessible
Each schedule can store 11 distinct and totally different parameters
All schedules retained in memory with power off
It is NOT NECESSARY to program functions not required
Four Cycle Modes can be programmed for complex welding schedules
Select and Program up to 3 VALVE CIRCUITS, STANDARD
Independently selectable and programmable
Process control outputs
External Schedule Select
Anti-Tiedown Initiations
Forge Delay
Versatile Weld Stepper
Control can be INTERFACED with external Programmable Logic Control (PLC); Advanced interfaces available
Selected Heat used SIMULTANEOUSLY on 3 Contactor Outputs.
Transformers can be connected in an outside delta, inside delta, or “Y” configurations.
Optional Functions:
Program Lockout Switch
Schedule Select
RS232 Port Interface
Remote Date Entry
Valve Select (One of Seven) Option
CABINET STYLE & DIMENSIONS
CONTACTOR STYLE & RATINGS
STYLE
H
W
D
AIR COOLED
WATER COOLED
D or T
610 mm
24"
645 mm
25-3/8"
254 mm
10"
Firing Circuit or 300A
1200A
LS or LF
914 mm
36"
797 mm
31-3/8"
254 mm
10"
Firing Circuit or 300A
1200A
1800A
HS or HF
1067 mm
42"
949 mm
37-3/8"
254 mm
10"
300A
1200A
1800A
2200A
Unique to ENTRON. All EN1003 3 Phase DC Controls in L & H Cabinets feature provisions for field installation or change of circuit breakers.
All SCR contactors complete with temperature limit switch.
Circuit Breakers available in L and H cabinets only. Consult factory for Circuit Breaker pricing. 100, 200 and 400 ampere
Circuit Breakers are available in L and H cabinets with right hand, flange mounted operator installed within the cabinet.
Consult factory for availability of 600 and 800 ampere Circuit Breakers.
See COMPREHENSIVE PRICE LIST for a complete list of Options, Circuit Breakers, Accessories and Special Features.
EN1003
D Cabinet
Style L Cabinet
914 mm x 797 mm x 254 mm
36″ x 31-3/8″ x 10″